For laboratory research use only. Not for human or veterinary use.
⚠ For research purposes only — This certificate relates to the referenced lot only and is not an approval for human or veterinary use.
← Back to MOTS-C
Atlas LabsQuality Control · Released Records

Certificate of Analysis

DOC QC-COA-0108-A2705 · REV 1
ProductMOTS-C
SKUATL-0108
LotA2705
FormatLyophilized · 10 mg
TestedAug 2026
Retest datePLACEHOLDER
CAS1627580-64-6
Storage−20 °C · desiccated
DispositionRELEASED

Test results

Release test results for MOTS-C lot A2705
TestMethodSpecificationResultVerdict
AppearanceVisual White to off-white solidWhite lyophilized solid PASS
PurityRP-HPLC, 220 nm ≥ 95.0%99.33% PASS
Net peptide contentHPLC 10 mg ± 2%10.09 mg PASS
IdentityESI-MS Observed mass conforms to theoreticalConforms PASS
Fentanyl screenImmunoassay Not detectedNot detected PASS
Heavy metalsICP-MS Not detectedNot detected PASS
SterilityPCR No growthNo growth PASS
EndotoxinLAL, USP <85> < 0.5 EU/mL< LOD PASS

Chromatogram · RP-HPLC, 220 nm

12.4 min · 99.33% RRT 1.28 · 0.09% 01530 min
FIG 1 · MAIN PEAK 12.4 MIN, 99.33% AREA · LARGEST IMPURITY 0.09% · PLACEHOLDER TRACE, REPLACE WITH LAB EXPORT

Conclusion. Lot A2705 of ATL-0108 meets all release specifications and is approved for distribution for laboratory research use only. Testing performed by ILS Laboratories, an independent ISO 17025 accredited laboratory.

Analyst · PLACEHOLDERILS Laboratories · Aug 2026
QC Release · PLACEHOLDERAtlas Labs · Aug 2026
VERIFY THIS DOCUMENT
getatlaspeptides.com/coa/a2705
CODE ATL-A2705-5T2B